NewOctober 2026 release: John Deere sync redesign, rate min and max limits, yield report zones

Soil sampling requirements in Wisconsin

Soil sampling requirements in Wisconsin

State guidance: UW Extension A2100, Sampling Soils for Testing.

Soil sampling in Wisconsin: frequency, area, depth and cores

How often do you need to soil sample in Wisconsin?

When in the year should soil be sampled in Wisconsin?

How many acres can one soil sample cover in Wisconsin?

  • UW Extension A2100, Sampling Soils for Testing Official guidance One composite per 5 acres (2.02 ha) on responsive fields and fields not sampled in the past 4 years. Fewer samples on nonresponsive fields tested within 4 years (Table 1).

How deep should soil samples be taken in Wisconsin?

  • UW Extension A2100, Sampling Soils for Testing Official guidance Plow depth or at least 6 inches (15.24 cm). Chisel or disk: three quarters of tillage depth. Ridge till: 6 inches on ridges, 4 in furrows. No-till: 6 to 7 inches (17.78 cm) for fertilizer advice, plus 2 inches for pH if an acid layer is suspected.

How many cores go into one soil sample in Wisconsin?

How many soil samples does a 100-acre field need in Wisconsin?

UW Extension A2100, Sampling Soils for Testing: A uniform 100-acre field needs at least 20 composite samples of no more than 5 acres each, and at least 200 cores in all, 10 per sample.

Samples and cores for any field size

Soil sampling rules in Wisconsin, with the exact wording of each source
Country / region Purpose / programme Time / frequency Area per sample Method Depth Cores Status and source
United States
WisconsinUnited StatesWisconsin only. Other states set their own rules.Routine soil fertility samplingUW Extension A2100, Sampling Soils for Testing
  • Repeat At least every 4 years. Sands and loamy sands every 2 years.
  • Season Any convenient time; fall may be best, so lime and fertilizer advice arrives in time. Hayfields after any cutting. Stay consistent from one year to the next.
One composite per 5 acres (2.02 ha) on responsive fields and fields not sampled in the past 4 years. Fewer samples on nonresponsive fields tested within 4 years (Table 1).W-shaped pattern for a whole field composite. Unaligned grid-point sampling at 200 feet (about 1 acre) or, on nonresponsive fields, 300 feet (2 to 2.5 acres). Zone (smart) sampling.Plow depth or at least 6 inches (15.24 cm). Chisel or disk: three quarters of tillage depth. Ridge till: 6 inches on ridges, 4 in furrows. No-till: 6 to 7 inches (17.78 cm) for fertilizer advice, plus 2 inches for pH if an acid layer is suspected.At least 10 cores per composite. 10 to 20 cores give a more representative sample.Official guidanceUW Extension A2100, Sampling Soils for Testing (PDF)
Who it applies to, the exact wording and every source
Who it applies to
Advice from the public land-grant university extension service for Wisconsin. Not law in itself; plans prepared to the NRCS 590 standard follow its sampling techniques.
Laboratory and analysis
A Wisconsin certified laboratory, for plans that must follow the NRCS 590 standard.
In force from
Under review
Legal text
University of Wisconsin-Extension A2100, Sampling Soils for Testing (Peters and Laboski, 2013)

The wording in the source

Timing

Area per sample

  • For responsive fields, as well as all fields that have not been sampled in the past 4 years, take one composite sample for every 5 acres.

    A2100 p. 3, step 3

  • Table 1. Recommended sample intensity for uniform fields: fields tested more than 4 years ago OR fields testing in the responsive range, all fields, 1 sample/5 acres; nonresponsive fields tested within past 4 years, 5–10 acres 2, 11–25 acres 3, 26–40 acres 4, 41–60 acres 5, 61–80 acres 6, 81–100 acres 7

    A2100 p. 1, Table 1 (transcribed)

Method

  • use a W-shaped sampling pattern (as shown in Figure 1) over the whole area the sample represents.

    A2100 p. 1

  • Where there is no information about the P or K status of the field or where previous tests were in the responsive range, a 200-foot grid size should be used. This is equivalent to approximately one soil sample per acre.

    A2100 p. 2, site-specific management

  • Fields that have soil test P and K levels in the nonresponsive categories should be grid-point sampled on a 300-foot grid. This is equivalent to one soil sample for every 2 to 2.5 acres.

    A2100 p. 2

  • Smart (zone or directed) sampling. Another approach gaining support among researchers is smart sampling, also known as directed or management zone sampling.

    A2100 p. 3

Depth

Cores

  • Each sample should be made up of a minimum of 10 cores to ensure accurate representation of the nutrient needs of the field.

    A2100 p. 1

  • Research has shown that taking 10 to 20 cores provides a more representative sample of the area than when samples are made up of fewer cores.

    A2100 p. 1

Laboratory and analysis

Sources

Sources re-checked every two months, last update October 2026. Reviewed by GeoPard editorial team.

United States: federal rules and every other state

Soil sampling regulations in every country

Report an outdated requirement: info@geopard.tech

Plan the points to the rule that applies

Set the area per sample, the cores and the depth your rule asks for. GeoPard places the points on a grid or by zone, routes the walk, prints the labels and takes the plan to the field on a phone.

wpChatIcon
wpChatIcon

    Request Free GeoPard Demo / Consultation








    By clicking the button you agree our Privacy Policy. We need it to reply to your request.

      Subscribe


      By clicking the button you agree our Privacy Policy

        Send us information


        By clicking the button you agree our Privacy Policy